Pages

Flow Diagram of Urea Production Process from Ammonia and Carbon-dioxide

Urea is manufactured by reacting ammonia and carbon dioxide in an autoclave to form ammonium carbamate. The operating temperature is 135oC and 35 atm pressure, the chemical reaction is an endothermic reaction and so ammonia is maintained in excess to shift the equilibrium towards urea formation.  Urea production is based on two main reactions.

1. Formation of ammonium carbamate
2. Dehydration of  ammonium carbamate to produce molten urea
a flow sheet for production of urea by continuous process from ammonia and carbon dioxide
Urea Production from 
 NH3 and CO2
Description of flow sheet:



1. Ammonia pumping: Liquid ammonia is pumped from the multistage pump which maintains the reaction pressure in the vertical stainless steel vessel

2. Carbon dioxide compression: ammonia plant directly boost the carbon dioxide from the compression section as it readily forms at the CO2 section of the ammonia production plant.

3. Urea synthesis tower: It is lined with a film of oxides to protect from corrosion. Catalyst bed is placed on the inner side of the autoclave structure and 180- 200 atm pressure at a temperature about 180-200 deg centigrade is maintained. Plug flow operation takes places and molten urea is removed from the top of the tower.

4. Distillation tower and Flash drum: This high-pressure slurry is flashed to 1 atm pressure and distilled to remove excess ammonia and decomposed ammonia carbamate salts are removed and recycled.

5. Vacuum Evaporator: The solution is fed to vacuum evaporator for concentrating the slurry.

6. Prilling Tower: It is dryer where the molten slurry is passed from the top of the tower into a bucket which rotates and sprinkles the slurry and air is passed from the bottom. All the moisture is removed as the urea form into granules during its journey to the bottom of the tower. These granules are sent by conveyor to the bagging section.

Biuret Formation:

Two moles of urea is converted into one mole of biuret and one mole of NH3 by heating.
2 NH2CONH2-------------> NH2CONHCONH2 + NH3
Because the biuret is injurious to germinating seeds, and pineapple and citrus trees wither when the fertilizer is sprayed on the leaf. The biuret content in fertilizer grade urea on the world market is required to be below 1.0%. biuret forms almost everywhere in urea production steps.
The following conditions are favourable for biuret formation.
• High residence times.
• High temperature.
• Low amount of water.

Process Water Treatment:
As already pointed out in the process description, the liquid effluent treatment section consists mainly of a distillation column to purify the wastewater, a hydrolyser to decompose the small percentage of urea into ratio NH3and CO2 which are eventually stripped in the lower section of the same column.
The condensed vapours from first and second vacuum systems, containing urea, ammonia and CO2 are collected in the process condensate tank. In this tank, the carbonate close drain is also fed by the centrifugal pump and are recycled.

A simple description which gives an idea of the urea manufacturing process with plant layout:



Reactor effluent:
The reactor effluent which consists of a liquid phase along with certain percentage inerts and reactants in a vapour phase, fed to the H.P. stripper where the first carbamate decomposition occurs. The vapour phase containing most of the inert gases then flows to the carbamate condenser together with the carbamate recycle from the medium pressure section. Only before re-injecting the carbamate into the reactor, the inert gases are separated from the liquid phase-in the carbamate separator and fed to the MP decomposer.

H.P. Stripper:

It is the falling film type heat exchanger. It containing 2429 tubes with some space above the tubes and below the tubes. In the above space, a 0.315m height pall rings bed arranged. A sieve tray is fitted above the packed bed. The tubes are fitted with ferrules have three tangentially drilled distribution holes. Tubes are made of titanium and shell side fluid is the medium pressure saturated steam.

The reaction product leaving the reactor flow to the steam heated falling film stripper which operates at about 144-146Kg/cm2 pressure. The liquid from the feed distributor pipe is evenly distributed onto the packed bed by means of a preheated sieve having 1400 holes. The mixture is heated up as it flows into the vertical tubes of the falling film exchanger. The CO2 content of the solution is reduced by the stripping action of the ammonia as it boils out of the solution. The carbamate decomposition heat is supplied by medium pressure saturated steam, where the latent heat of condensation of saturated steam is taken by carbamate solution. In the falling film exchanger, the principle advantages are a high rate of heat transfer, no internal pressure drop, short time of contact.

Decomposition is promoted by heating and stripping CO2 by vaporized excess NH3, under the same pressure level as urea reactor. Stripper used is falling film type, decomposed and vaporized gases and liquid effluent are therefore in counter-current contact and CO2 concentration in the liquid is gradually reduced from the top to bottom of the stripper tube. As NH3 rich gas (CO2lean gas) rises from the lower parts of the tube, then the gas at upper parts of the tube becomes an NH3 rich gas as compared with the equilibrium composition and the decomposition reaction in liquid phase corrects the deviation from the equilibrium (the stripping effect). Decomposition at high pressure requires high temperature which means that much biuret has formed and the liquid becomes corrosive, but excess ammonia and the use of titanium in the stripper permit minimizing the problems.

The urea solution with part of inerts is coming from the bottom of the stripper enters into the medium pressure decomposition in urea purification section. The overhead gases from the top of the stripper mixed with recovered solution from medium pressure absorber and then pressurized to 180kg/cm2 in H.P. carbamate pumps and preheated in carbamate pre-heater by using steam condensate flowing to battery limits then this mixture enters tube side of carbamate condenser where heat of reaction of reaction-1 and condensation of carbamate gases is removed by production of steam at 3.5 to 4.5 kgf/cm2 on the shell side by vaporization of water. The condensate from the condenser with few inert gases is entered into the carbamate separator. Carbamate separator is the cylindrical empty vessel in which separation of carbamate solution from inert gases will take place, carbamate solution from the bottom of the separator is recycled to the reactor by means of an ejector.

The non-condensate gases from the top of the separator consist mainly of inert gases, with a small amount of NH3 and CO2 are passed through the split range controller to the medium pressure decomposer holder to utilize the heat of these for that decomposition.


UREA PURIFICATION:

Urea purification takes place in three stages at decreasing pressures as follows: First stage at 18kgf/cm2 Second stage at 4.5kgf/cm2 Third stage at 0.35kgf/cm2 It is pointed out that the exchangers where the urea purification occurs are called decomposer. the upper part of the medium pressure inert washing tower consists of three valve trays. Where the inert gases are subjected to a final scrubbing or washing by means of some absorption water. In this way, the inerts are sent to vent stack practically free from ammonia.

Prevention of explosion hazard by gases vented to the atmosphere:

CO2 fed to the reactor normally contains a small percentage of H2, CH4 and CO in addition to inerts like N2 and Ar. These gases plus a few gases introduced into the plant with NH3 coming from B.L together with CO2 contained in passivation air could give rise to explosively problems when vented into the atmosphere from MP inerts washing tower. As a matter of fact, this problem is minimized in Snamprogetti urea plants. Since the quantity of passivation air used is far lower than the one used in other processes. Thus the O2 to the flammable gases ratio in the vented gases does not justify the use of an H2 removal system on the CO2 stream from B.L


Purification and recovery stage at 4.5 kg/cm2:

L.P.Decomposer (LPD):

This is also the falling film type heat exchanger. It is also constructed the same as to MP decomposer, the packed bed height, equipment divisions and construction are the same.
The lower the pressure, the better the prevention of NH3 and CO2 loses from the system, but the recovered solution becomes weaker. Which means that excess water is recycled to the synthesis loop, the operating conditions of L.P decomposer are selected at 3.5kgf/cm2 pressure decomposer (falling film type). The gases leaving the top separator are mixed with the dilute carbon solution coining from wastewater treatment and sent to the ammonia preheater, where they are practically absorbed and condensed.

The ammonia preheater is the shell and tube(1-4 pass) heat exchanger, in which LPD vapours are condensed and feed NH3 to the reactor is heated. While depressurizing(drawing tube side NH3 loop, case must be taken to avoid freezing of water) solution on the shell side of this preheater.
From the above condensate with uncondensed gases then enter the LP condenser, where the residue absorption and condensation heat is removed by cooling water. The liquid phase,, with remaining inert gases, is sent to the carbonate solution vessel.

The carbonate solution tank is a horizontal cylindrical vessel. It is constructed with inerts washing tower above the tank and is located slightly taper to the ground to maintain the solution head for pumps at a low level also. In shutdown followed by emptying of high-pressure equipment, the recovered NH3, CO2 in the low-pressure stage is also stored in their tank. The level of this tank should be maintained low in order to recover all carbonate in case of a shutdown.

The inert gases leaving from carbonate solution tank enters into low-pressure inerts washing tower which is located on the tank with the packed bed. The inerts are washed in this tower by using water in the countercurrent flow. The inerts which are leaving from the washing tower are vented to stack, which is practically free from NH3.


Purification and recovery stage at 0.35kg/cm2:

Vacuum pre-concentrator:

This is also the falling film type heat exchanger. It is also constructed the same as to above decomposers with bell distributor.
The solution leaving(the bottom of low-pressure decomposer is expanded at 0.35 kgf/cm2 pressure and enters the vacuum pre-concentrator) falling film types as with the help of tangentially inlet duct. Top separator where the released flash gases are removed before the solution enters the tube bundle. Decomposition section where the last residual carbamate is decomposed and the required heat is supplied by the condensation of the gases coming from the medium pressure decomposer separator.
The gases leaving the pre-concentrator top are routed to the vacuum duct where condensation takes place. The urea solution, collected at the bottom of the pre-concentrator holder is sent to the vacuum section by using the centrifugal pump. The pre-concentrator is able to save a lot of pressure stream in the evaporator permits to concentrate the urea solution from 70-75% to about 85-88% wt. Low-pressure section for urea production

UREA CONCENTRATION :

As it is necessary, in order to prill urea, to concentrate the urea solution up to 99.8% wt. The simplest and most widely used method is direct concentration, which consists of heating the solution under vacuum to remove water. Direct concentration is operated on the basis of the equilibrium vapour pressure of the urea solution.

Theoretically, to concentrate the solution without the deposit of crystals, the operating pressure should be kept over 0.3kh/cm2 abs.., 1360C int eh second vacuum system.The urea solution coming from vacuum pre-concentrator holder is sent to the first vacuum concentrator where it is heated up to above the boiling point of that liquid at the pressure of separator. The mixed phase coming out of concentrator enters the gas-liquid separator from where vapours are extracted by the second vacuum system, while the solution fed to the prilling section by using the centrifugal pump.
Both the 70-72% wt.urea solution from the L.P decomposer and the urea melt from the vacuum separator can be directed to the urea solution tank, so as to face any emergency situation in both the vacuum and prilling sections.


UREA PURIFICATION at  M.P. Decomposer: 

This is falling film type heat exchanger is divided into three parts. Top separator where the released flash gases are separated, middle decomposer where the carbamate decomposition will take place and bottom holder where the concentrated urea solution will holding. The decomposer tubes are fitted with ferrules having four tangentially distribution holes with equispaced. Packing bed of pall ring with 1.3m height and sieve plate for distribution is provided above the decomposer in the separator. To promote more decomposition it is necessary to that higher temperatures or to reduce to lower levels. M.P. Decomposed is operated at 17kgf/cm2 (g) and 156-158OC decomposed heat is being supplied from outside of tube by M.P. steam and M.P. condensate.

Flow diagram of urea production medium pressure section
Urea medium pressure 
section flow sheet
The solution with a low residual CO2 content, leaving the bottom of the stripper is expanded at the pressure of 18kgf/cm2 and enters at the top of the M.P. decomposer where the released flash gases are removed before solution enters the tube bundle. Where the residual carbamate is decomposed and the required heat is supplied by means of medium pressure saturated steam and medium pressure steam condensate which is coming from the stripper. Distribution of falling film is obtained by ferrules. After decomposition of carbamate, the concentrated urea solution with part of inert is collected in the holder and then flows to L.P. decomposer.
The NH3 and CO2 rich gas leaving the top of the separator are sent to vacuum pre-concentrator, where they are partially absorbed in the aqueous carbonate solution coming from the urea purification section at 4.5kgf/cm2. The absorption and condensation of gases are removed by evaporating water from urea solution, thus allowing a considerable saving of L/P/ steam in the evaporation stages. Then the gases enter the M.P. condenser where the residue absorption and condensation of the heat of gases are removed by cooling water. In the condenser, CO2 is almost totally absorbed. The mixture of M.P. condenser flows to the medium pressure absorber.

M.P. Absorber:
It is the bubble cap tray type column contains 4 numbers of trays having bubble cap risers fitted with bell caps. It contains a sparger pipe distributor at the bottom. The absorber performs CO2 absorption and NH rectification.
Reflux NH3 is drawn as part from the NH3 booster pump and fed to the absorber on the top tray and the aqueous ammonia solution which in coming from M.P.inerts washing tower is fed on the third tray by means of a centrifugal pump and tray washing provision is also there.
Urea production equipment of medium pressure section
Image of a medium pressure
section of a urea production
Partially condensed NH3 -CO2-H2O mixture from M.P. condenser enters the bottom of the column, where it is distributed is carbamate solution by means of sparger pipe distributor. Uncondensed gases consisting of NH3 , CO2, H2O and inerts rising from the bottom are absorbed by cold liquid NH3 reflux in the upper section of the column. Most of the CO2 and H2O condenses as ammonium carbamate and fall back to the bottom. Condensation heat is removed by evaporation of ammonia. Thus a stream of inert gases saturated with NH3 leaving the top of the absorbers rectification section. The bottom solution is recycled to urea synthesis and high-pressure recovery section by H.P. carbonate pump. Ammonia vapours with inert gases leaving the top of the column is partially condensed in ammonia condenser by heat exchange with cooling water and then the liquid and gaseous ammonia phases are returned to ammonia receiver.


Ammonia Receiver:
It is the horizontal cylindrical vessel fitted with ammonia recovery tower. The tower is installed on the receiver with a 3m packing bed height of pall rings and contain distribution sieve tray above the packed bed. The receiver is located slightly tapper to the ground.
The ammonia which is received from battery limits containing 5PPM oil. It causes the foaming in the synthesis section, to avoid this foaming the oil should be separated from ammonia. In the above receiving tank, the oil will separate by density separation and comes towards the down end of the tank. This oil will drain periodically.
• The function of this receiver tank is to receive and act as buffer storage for ammonia received from battery limit.
• To receive ammonia recovered during plant shut down.
• To receive ammonia condensed in the recovery system.

The inert gases containing residual ammonia leaving the receiver enters the ammonia recovery tower, where the pure ammonia coming from B.L. is fed at the top of the tower. In the tower, the inert gases containing NH3 and pure liquid NH3 are brought in contact with each other in countercurrent flow to recover some ammonia from inerts.

The inert gases containing residual ammonia are sent to the medium pressure falling film absorber(inert washing tower) where they meet in a counter-current water flow which absorbs gaseous ammonia. The heat of absorption is removed by cooling water. From the bottom of the absorber, the water-NH3 solution is recycled back to the medium pressure absorber by means of a centrifugal pump. Tower operating at a pressure 2.5 kgf/cm2 before entering the distillation tower the process condensate is preheated in the exchangers where the heating medium is the purified condensate flowing out the tower.
Since the solution is contaminated by urea, after a first stripping in the upper part of the tower, it is pumped into the hydrolyser where the urea is decomposed by means of the stream at 37 kgf/cm2 , 370oC. Before entering the hydrolyser, the solution is preheated in the exchanger with the solution coming out from the hydrolyser.

The hydrolysis reaction of urea is the opposite of that occurring in the reactor.

NH2CONH2 + H2O ------->2NH3 + CO2 + Heat

Therefore urea decomposition is favoured by high temperature, low pressure and NH3 & CO2 deficiency. Also, a sufficiently long residence time has proved to be an important parameter. In order to eliminate NH3 and CO2 as far as possible before feeding the hydrolyser the wastewater coming out from the vacuum condensers is first stripped in the column. Moreover, a series of baffles in the hydrolyser provided a plug flow effect, thus avoiding back mixing. Also, the continuous removal of hydrolysis reaction and this encourages the decomposition of urea.
Flow sheet of urea formation process
Urea High 
Pressure section
The vapours leaving the hydrolyser, jointly with the vapours coming from the distillation tower are condensed in the distillation tower overhead condenser. Where the condensation heat is removed by cooling water. From this condenser, the carbonate solution flows to the reflux accumulator from part of the solution fed to the distillation column by using the pump. The purified waste from the bottom of the distillation tower is cooled.


UREA PRILLING: PRILL TOWER:

It is a cylindrical vertical tower with a height of 100m, in which urea prilling takes place. It consists of prill section the top and scrapper at the bottom. Prill tower contains bottom lowers(window) and top lowers(windows) also. In the prill section bucket (Tuttle type) is there. The tower is coated inside with anti-corrosive plant. This is a natural draft
Prill tower.
The molten urea leaving the second vacuum holder is sent to the prilling bucket by means of a centrifugal pump. The bucket contains no. of holes to the wall. The urea coming out of the rotating bucket in the form of drops fall along with the prilling tower and arid encounters cold air flow which causes its solidification.
The molten urea drops coming from bucket contains is at a temperature of1330C
There will be heat transfer from drops to air, thus reducing the temperature of drops and increasing the temperature of the air. The heated air tries to go up, due to that flow of air, some vacuum is created at the glass. The bottom air will try to cover the above vacuum thus creating the natural draft. The air will enter the prill tower through bottom lowers and vented to the atmosphere through top lowers.
The heated air with a few parts of urea dust enters the scrubbing section where the urea dust will recover from the air by scrubbing of air with DM water and the free from urea dust is vented to atmosphere.
The molten urea drops from bucket fall down along the prilling tower. Due to the countercurrent flow of air, the temperature of molten urea will decrease and form as a prill. The solid prills falling to the bottom of the prilling tower are fed to a belt conveyor by a rotary scraper. From here they are sent to the automatic weighing machine and to the urea storage, bagging section.



DEDUSTING SYSTEM:
The urea melt coming out of the bucket in the form of droplets and while falling inside the prill tower encounters a countercurrent flow of cold air causes solidification. Hot air leaving prill tower top consists of fine urea dust and free ammonia. In order to prevent pollution caused during the process of prilling. During system has been incorporated at prill tower top. The system also recovers urea, which is recycled back into the system.

Operation:
In the dedusting tank, air travels in two chambers and a stainless steel partition wall which is hanging from the top separates these two chambers. The three recirculation pumps take suction deduction chamber with the help of scrubber nozzles with an angle of 10 deg and due to this spraying action, sir is sucked into the first chamber (annual scrubbing chamber). Urea gets dissolved while exhaust air travelling from top to bottom in annular scrubber chamber and then it enters the second chamber of the dedusting sump, where demister pads are provided at the top. A process condensate pump is sprayed on demister pads. By nozzles with 90deg.angle, and this system is operated by PLC (programmable logic control). Before taking DDS in line top louvres are be kept closed. Make up liquid for the dedusting sump is done by a control valve and after attaining required concentration the solution is drained to urea lumps dissolving tank. Maximum allowable urea dust to atmospheric air is 3Omg/Nm2 of air. An energy-efficient process for urea synthesis must fulfil the following parameters.
• The high conversion efficiency of CO2 in urea synthesis reactor, in order to minimize the heat required for decomposition of unconverted carbamate.(Achieved by optimization of parameters in the urea reactor).
• Efficient decomposition of carbamate and efficient separation of carbamate decomposition products(CO and NH3 ), as well as of excess ammonia.(Optimization of process parameters in the stripper and decomposer)
• Maximum recovery and efficient utilization of heat formed by absorption and reaction of NH3 and CO released from the stripper and decomposition. (Optimization of process parameters in the carbamate condenser, the MP decomposes and MP absorber).





photo of urea production equipments of high pressure section
Urea formation and 
high-pressure section photo